Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pharmaceuticals (Basel) ; 13(4)2020 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-32316568

RESUMO

Carvedilol (CRV) is a non-selective blocker of α and ß adrenergic receptors, which has been extensively used for the treatment of hypertension and congestive heart failure. Owing to its poor biopharmaceutical properties, CRV has been incorporated into different types of drug delivery systems and this necessitates the importance of investigating their compatibility and stability. In this sense, we have investigated the applicability of several electroanalytical tools to assess CRV compatibility with lipid excipients. Voltammetric and electrochemical impedance spectroscopy techniques were used to evaluate the redox behavior of CRV and lipid excipients. Results showed that Plurol® isostearic, liquid excipient, and stearic acid presented the greatest anode peak potential variation, and these were considered suitable excipients for CRV formulation. CRV showed the highest stability at room temperature and at 50 °C when mixed with stearic acid (7% w/w). The results also provided evidence that electrochemical methods might be feasible to complement standard stability/compatibility studies related to redox reactions.

2.
Med Mycol ; 58(7): 881-886, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-32022862

RESUMO

The hospital environment requires special attention to air quality, since it needs to be healthy for the protection of patients and health professionals in order to prevent them against hospital infections. The objective of this study was to isolate, identify and evaluate the susceptibility profile of isolated fungi from two hospitals. For air sampling the impaction (Spin Air, IUL®) and passive sedimentation methods were used. For the isolation of fungi from surfaces, contact plates (RODAC®) were used. The identification of the fungi was performed by observing the macroscopic and microscopic aspects of the colonies, whereas for better visualization of fruiting structures, the microculture technique was performed on slides. To evaluate the susceptibility profile, the broth microdilution test recommended by CLSI was performed. Thirty-five isolates were identified: Aspergillus flavus (12), Aspergillus fumigatus (11), Aspergillus niger (1), Aspergillus terreus (2), Penicillium spp. (7), and Fusarium spp. (2) in the hospitals evaluated. All isolates had a minimum inhibitory concentration (MIC) more than 128 µg/ml for fluconazole; 0.5 to 4.0 µg/ml for amphotericin B (hospital 1), and all isolates from haospital 2 had MIC ≥2.0 µg/ml. In hospital 1, MIC for posaconazole ranged from 0.25 µg/ml to ≥32 µg/ml, and hospital 2 ranged from 0.5 to 1.0 µg/ml. The monitoring and evaluation of air quality and surfaces are essential measures for prevention and control of hospital infections, as these microorganisms are becoming increasingly resistant to antimicrobial agents, thus making treatment difficult, especially in immunocompromised individuals.


Assuntos
Antifúngicos/administração & dosagem , Aspergillus/isolamento & purificação , Equipamentos Médicos Duráveis/microbiologia , Fusarium/isolamento & purificação , Doença Iatrogênica/prevenção & controle , Penicillium/isolamento & purificação , Esterilização/métodos , Humanos , Unidades de Terapia Intensiva , Salas Cirúrgicas , Estudos Prospectivos , Sala de Recuperação , Medição de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...